title: What setup prerequisites and tools are required for installing a Verv Connect device, especially for electrical engineers?
description: Review the full installation checklist and electrical prerequisites for setting up a Verv Connect device. Includes required tools and key notes for 3-phase compatibility.
---

[Skip to content](https://marketing.verv.energy/en-gb/knowledge-base/what-setup-prerequisites-and-tools-are-required-for-installing-a-verv-connect-device-especially-for-electrical-engineers#main-content)

English - United Kingdom

Show submenu for translations

[![Knowledge Base (500 x 200 px) (1)](https://marketing.verv.energy/hs-fs/hubfs/Knowledge%20Base%20(500%20x%20200%20px)%20(1).png?width=250&height=100&name=Knowledge%20Base%20(500%20x%20200%20px)%20(1).png)](https://marketing.verv.energy/en-gb/knowledge-base?hsLang=en-gb)

Open main navigation

Close main navigation

- English - United Kingdom
  
  Show submenu for translations
- [Verv Portal](https://portal.verv.energy/auth/login)

[Verv Portal](https://portal.verv.energy/auth/login)

 How can we help you?

- There are no suggestions because the search field is empty.

1. [Verv Knowledge Base](https://marketing.verv.energy/en-gb/knowledge-base?hsLang=en-gb)
2. [Getting started](https://marketing.verv.energy/en-gb/knowledge-base/getting-started?hsLang=en-gb)

# What setup prerequisites and tools are required for installing a Verv Connect device, especially for electrical engineers?

Before installing a Verv Connect device, electrical engineers should ensure they have the correct tools and electrical setup to support a smooth and safe installation. Here's a checklist of prerequisites and required tools:

#### **Tools Required:**

- Power drill
- Circular hole cutting drill bit or **step drill bit** (20mm–25mm)
- **Multimeter**
- **Phillips screwdriver**
- **Standard flathead screwdriver**

#### **Electrical Requirements:**

- Ensure **both live and neutral supply** and an earth is available
- For **3-phase installations**, all **three phases plus a neutral** are required 
    - *Note:* A three-phase motor **without a neutral supply** is **not compatible** with the Verv 3-phase smart isolator
    - Note: It is possible to run a three phase isolator as a single phase isolator by connecting to L1, Neutral & Earth

Verifying both the toolset and electrical conditions before installation will help avoid delays and ensure safety compliance during setup.

- [Getting started](https://marketing.verv.energy/en-gb/knowledge-base/getting-started?hsLang=en-gb)
- [Portal Set Up](https://marketing.verv.energy/en-gb/knowledge-base/portal-set-up?hsLang=en-gb)
- [Ongoing Support](https://marketing.verv.energy/en-gb/knowledge-base/ongoing-support?hsLang=en-gb)
- [FAQs](https://marketing.verv.energy/en-gb/knowledge-base/faqs?hsLang=en-gb)
- [Technical Specifications](https://marketing.verv.energy/en-gb/knowledge-base/technical-specifications?hsLang=en-gb)
- [Troubleshooting](https://marketing.verv.energy/en-gb/knowledge-base/troubleshooting?hsLang=en-gb)
- [Licensing and Pricing](https://marketing.verv.energy/en-gb/knowledge-base/licensing-and-pricing?hsLang=en-gb)
- [Security and Compliance](https://marketing.verv.energy/en-gb/knowledge-base/security-and-compliance?hsLang=en-gb)
- [Getting Help](https://marketing.verv.energy/en-gb/knowledge-base/getting-help?hsLang=en-gb)

[![Green Device](https://marketing.verv.energy/hs-fs/hubfs/Green%20Device.png?width=50&height=50&name=Green%20Device.png "Green Device")](http://www.verv.energy)

Sustainable Ventures  
County Hall  
Belvedere Road  
London  
SE1 7PB

Copyright © 2024, Verv Energy (Green Running Ltd)